3.3.3.159. NXtransmission¶
Status:
application definition (contribution), extends NXobject
Description:
Application definition for transmission experiments
Symbols:
Variables used throughout the experiment
N_wavelengths: Number of wavelength points
N_scans: Number of scans
- Groups cited:
NXattenuator, NXdata, NXdetector, NXentry, NXfabrication, NXgrating, NXinstrument, NXmonochromator, NXsample, NXslit, NXsource, NXuser
Structure:
ENTRY: (required) NXentry
This application definition
definition: (required) NX_CHAR ⤆
An application definition for transmission. ...
An application definition for transmission.
Obligatory value:
NXtransmission
@version: (required) NX_CHAR ⤆
Version number to identify which definition of this application definition ...
Version number to identify which definition of this application definition was used for this entry/data.
@url: (required) NX_CHAR
URL where to find further material (documentation, examples) relevant to t ...
URL where to find further material (documentation, examples) relevant to the application definition.
start_time: (required) NX_DATE_TIME ⤆
Start time of the experiment.
experiment_identifier: (required) NX_CHAR ⤆
Unique identifier of the experiment, such as a (globally persistent) ...
- Unique identifier of the experiment, such as a (globally persistent)
unique identifier.
The identifier is usually defined by the facility or principle investigator.
The identifier enables to link experiments to e.g. proposals.
experiment_description: (optional) NX_CHAR ⤆
An optional free-text description of the experiment. However, details of the ...
An optional free-text description of the experiment. However, details of the experiment should be defined in the specific fields of this application definition rather than in this experiment description.
acquisition_program: (optional) NXfabrication
@url: (recommended) NX_CHAR
Website of the software
Commercial or otherwise defined given name to the program that was ...
Commercial or otherwise defined given name to the program that was used to generate the result file(s) with measured data and metadata.
identifier: (required) NX_CHAR ⤆
Version number of the program that was used to generate the result ...
Version number of the program that was used to generate the result file(s) with measured data and metadata.
Contact information of at least the user of the instrument or the investigat ...
Contact information of at least the user of the instrument or the investigator who performed this experiment. Adding multiple users if relevant is recommended.
Name of the user.
affiliation: (required) NX_CHAR ⤆
Name of the affiliation of the user at the point in time when the experime ...
Name of the affiliation of the user at the point in time when the experiment was performed.
Street address of the user’s affiliation.
Email address of the user.
url: (recommended) NX_CHAR
Author ID defined by reasearch id services, e.g. orcid (https://orcid.org/).
telephone_number: (recommended) NX_CHAR ⤆
Telephone number of the user.
instrument: (required) NXinstrument ⤆
common_beam_depolarizer: (required) NX_BOOLEAN
If true, the incident beam is depolarized.
polarizer: (required) NX_NUMBER {units=NX_ANGLE}
Polarizer value inside the beam path
time_points: (optional) NX_NUMBER (Rank: 1, Dimensions: [N_scans]) {units=NX_TIME}
An array of relative scan start time points.
measured_data: (required) NX_NUMBER (Rank: 2, Dimensions: [N_scans, N_wavelengths])
Resulting data from the measurement. ...
Resulting data from the measurement. The length of the 2nd dimension is the number of time points. If it has length one the time_points may be empty.
manufacturer: (recommended) NXfabrication
Manufacturer of the instrument.
common_beam_mask: (required) NXslit
Common beam mask to shape the incident beam
y_gap: (required) NX_NUMBER {units=NX_UNITLESS} ⤆
The height of the common beam in percentage of the beam
ref_attenuator: (required) NXattenuator ⤆
sample_attenuator: (required) NXattenuator ⤆
spectrometer: (required) NXmonochromator ⤆
wavelength: (required) NX_NUMBER (Rank: 1, Dimensions: [N_wavelengths]) {units=NX_LENGTH}
Wavelength value(s) used for the measurement. ...
Wavelength value(s) used for the measurement. An array of 1 or more elements. Length defines N_wavelenghts
spectral_resolution: (optional) NX_NUMBER {units=NX_WAVENUMBER}
Overall spectral resolution of this spectrometer. ...
Overall spectral resolution of this spectrometer. If several gratings are employed the spectral resoultion should rather be specified for each grating inside the NXgrating group of this spectrometer.
GRATING: (optional) NXgrating ⤆
angular_dispersion: (optional) NX_NUMBER
Dispersion of the grating in nm/mm used.
blaze_wavelength: (optional) NX_NUMBER {units=NX_LENGTH}
The blaze wavelength of the grating used.
spectral_resolution: (optional) NX_NUMBER {units=NX_WAVENUMBER}
Overall spectral resolution of the instrument ...
Overall spectral resolution of the instrument when this grating is used.
wavelength_range: (required) NX_NUMBER (Rank: 1, Dimensions: [2]) {units=NX_LENGTH}
Wavelength range in which this grating was used
DETECTOR: (required) NXdetector ⤆
wavelength_range: (required) NX_NUMBER (Rank: 1, Dimensions: [2]) {units=NX_LENGTH}
Wavelength range in which this detector was used
Detector type ...
Detector type
Any of these values:
PMT
|PbS
|InGaAs
response_time: (optional) NX_NUMBER {units=NX_TIME}
Response time of the detector
gain: (optional) NX_NUMBER
Detector gain
slit: (required) NXslit
Slit setting used for measurement with this detector
type: (required) NX_CHAR
Any of these values:
fixed
|servo
The lamp used for illumination
The type of lamp, e.g. halogen, D2 etc. ...
The type of lamp, e.g. halogen, D2 etc.
Any of these values:
halogen
|D2
spectrum: (optional) NX_NUMBER (Rank: 1, Dimensions: [N_wavelengths])
The spectrum of the lamp used
wavelength_range: (required) NX_NUMBER (Rank: 1, Dimensions: [2]) {units=NX_LENGTH}
Wavelength range in which the lamp was used
A default view of the data emitted intensity vs. wavelength. ...
A default view of the data emitted intensity vs. wavelength. From measured_data plot intensity and wavelength.
We recommend to use wavelength as a default attribute, but it can be ...
We recommend to use wavelength as a default attribute, but it can be replaced by any suitable parameter along the X-axis.
Hypertext Anchors¶
List of hypertext anchors for all groups, fields, attributes, and links defined in this class.
/NXtransmission/ENTRY/instrument/common_beam_depolarizer-field
/NXtransmission/ENTRY/instrument/common_beam_mask/y_gap-field
/NXtransmission/ENTRY/instrument/DETECTOR/response_time-field
/NXtransmission/ENTRY/instrument/DETECTOR/wavelength_range-field
/NXtransmission/ENTRY/instrument/ref_attenuator/attenuator_transmission-field
/NXtransmission/ENTRY/instrument/sample_attenuator/attenuator_transmission-field
/NXtransmission/ENTRY/instrument/SOURCE/wavelength_range-field
/NXtransmission/ENTRY/instrument/spectrometer/GRATING/angular_dispersion-field
/NXtransmission/ENTRY/instrument/spectrometer/GRATING/blaze_wavelength-field
/NXtransmission/ENTRY/instrument/spectrometer/GRATING/spectral_resolution-field
/NXtransmission/ENTRY/instrument/spectrometer/GRATING/wavelength_range-field
/NXtransmission/ENTRY/instrument/spectrometer/spectral_resolution-field
/NXtransmission/ENTRY/instrument/spectrometer/wavelength-field